Simatic Cp 1543-1 Firmware vulnerabilities
4 known vulnerabilities in Simatic Cp 1543-1 Firmware from Siemens. 4 are rated high or critical, and 1 has been exploited in real attacks. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 7.5 High severity
SIMATIC CP 1543-1 V4.0: Incorrect Authorization
A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.
- 9.8 Critical severity
SIMATIC CP 1242-7 V2: Improper Encoding or Escaping of Output
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All v
- 10.0 Critical severity
SIMATIC CP 1242-7 V2: Out-of-bounds Write
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All v
- 7.5 High severity
Siemens SIMATIC CP 1543-1 Improper Privilege Management Exploited
A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be conf