SMA1000 vulnerabilities
15 known vulnerabilities in SMA1000 from SonicWall. 14 are rated high or critical, and 6 have been exploited in real attacks. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 7.2 High severity
SMA1000: Improper Limitation of a Pathname to a Restricted Directory
A Zip Slip vulnerability in the in the SMA1000 Appliance Management Console (AMC) interface allows an attacker to extract files outside the intended destination directory using a specially crafted archive, resulting in remote code execution.
- 7.8 High severity
SMA1000: Improper Neutralization of Special Elements used in an OS Command
Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability has been identified in the SMA1000 appliance which in specific conditions could potentially enable a remote authenticated attacker as a
- 10.0 Critical severity
SMA1000: Unintended Proxy or Intermediary
A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker could potentially exploit this vulnerability to direct the applianc
- 7.8 High severity
SonicWall SMA1000 Appliances OS Command Injection Exploited
Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote au
- 10.0 Critical severity
SonicWall SMA1000 Appliances Server-Side Request Forgery Exploited
A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. A remote unauthenticated attacker could potentially exploit this vulnerability to gain unauthorized access to sensitive fun
- 7.2 High severity
SonicWall SMA1000 Appliances Code Injection Exploited
Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administr
- 10.0 Critical severity
SonicWall SMA1000 Appliances Server-Side Request Forgery Exploited
A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. A remote unauthenticated attacker could potentially cause the appliance to make requests to unintended location.
- 7.2 High severity
SMA1000: Improper Handling of Unicode Encoding
Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN user to bypass Workplace/Connect Tunnel TOTP authentication.
- 7.2 High severity
SMA1000: Observable Response Discrepancy
An observable response discrepancy vulnerability in the SonicWall SMA1000 series appliances allows a remote attacker to enumerate SSL VPN user credentials.
- 7.2 High severity
SMA1000: Improper Neutralization of Special Elements used in an SQL Command
Improper neutralization of special elements used in an SQL command (“SQL Injection”) in SonicWall SMA1000 series appliances allows a remote authenticated attacker with read-only administrator privileges to escalate privileges to primary administrator.
- 6.6 Medium severity
SonicWall SMA1000 Missing Authorization Exploited
A local privilege escalation vulnerability due to insufficient authorization in the SonicWall SMA1000 appliance management console (AMC).
- 7.2 High severity
SMA1000: Server-Side Request Forgery
A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. By using an encoded URL, a remote unauthenticated attacker could potentially cause the appliance to make requests to unintended location.
- 7.2 High severity
SMA1000: Server-Side Request Forgery
A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface, which in specific conditions could potentially enable a remote unauthenticated attacker to cause the appliance to make requests to an unintend
- 9.8 Critical severity
SonicWall SMA1000 Appliances Deserialization Exploited
Pre-authentication deserialization of untrusted data vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) and Central Management Console (CMC), which in specific conditions could potentially enable a remote unauthenticated attack
- 7.5 High severity
SMA1000: Server-Side Request Forgery
A Server-Side Request Forgery (SSRF) vulnerability in SMA1000 appliance firmware versions 12.4.3-02676 and earlier allows a remote, unauthenticated attacker to cause the SMA1000 server-side application to make requests to an unintended IP address.