  • 8.8 High severity

    AC15: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11388Tenda

    A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is

  • 8.8 High severity

    AC15: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11387Tenda

    A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The expl

  • 8.8 High severity

    AC15: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11386Tenda

    A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack

  • 8.8 High severity

    AC20: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11385Tenda

    A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The affected element is the function sscanf of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to buffer overflow. The attack can be initiated remotely. The

  • 8.8 High severity

    AC23: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11356Tenda

    A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11328TendaEPSS 1.1%

    A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotel

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11327TendaEPSS 1.27%

    A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the att

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11326TendaEPSS 1.27%

    A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from rem

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11325Tenda

    A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11324Tenda

    A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be e

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11123Tenda

    A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published

  • 8.8 High severity

    AC18: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11122Tenda

    A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit i

  • 8.8 High severity

    AC18: Improper Neutralization of Special Elements in Output Used by a Downstream Component

    CVE-2025-11121TendaEPSS 3.52%

    A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The expl

  • 8.8 High severity

    AC8: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11120TendaEPSS 4.05%

    A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit

  • 8.8 High severity

    CH22: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11117Tenda

    A vulnerability was determined in Tenda CH22 1.0.0.1. This vulnerability affects the function formWrlExtraGet of the file /goform/GstDhcpSetSer. This manipulation of the argument dips causes buffer overflow. The attack is possible to be carried out remotely. T

  • 8.8 High severity

    AC21: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-11091Tenda

    A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remot

  • 8.8 High severity

    AC21: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10838TendaEPSS 1.06%

    A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely.

  • 8.8 High severity

    AC20: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10815Tenda

    A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this issue is the function strcpy of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. T

  • 8.8 High severity

    AC23: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10803Tenda

    A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer ove

  • 7.7 High severity

    An issue was discovered in Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01 allowing attackers…

    CVE-2025-57528Tenda

    An issue was discovered in Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01 allowing attackers to cause a denial of service via the funcname, funcpara1, funcpara2 parameters to the formSetCfm function (uri path: SetCfm).

  • 8.8 High severity

    AC9: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10443TendaEPSS 4.57%

    A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed

  • 8.8 High severity

    AC9: Improper Neutralization of Special Elements used in a Command

    CVE-2025-10442TendaEPSS 9.16%

    A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. Th

  • 9.8 Critical severity

    AC1206: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10432TendaEPSS 1.58%

    A vulnerability was found in Tenda AC1206 15.03.06.23. This vulnerability affects the function check_param_changed of the file /goform/AdvSetMacMtuWa of the component HTTP Request Handler. Performing manipulation of the argument wanMTU results in stack-based b

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57060Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the rules parameter in the dns_forward_rule_store function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    W30e Firmware: Stack-based Buffer Overflow

    CVE-2025-57086Tenda

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the String parameter in the formDeleteMeshNode function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 9.8 Critical severity

    W30e Firmware: Stack-based Buffer Overflow

    CVE-2025-57085Tenda

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57078Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the pppoeServerWhiteMacIndex parameter in the formModifyPppAuthWhiteMac function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    W30e Firmware: Stack-based Buffer Overflow

    CVE-2025-57087Tenda

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57072Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the staticRouteGateway parameter in the formSetStaticRoute function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57071Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the vpnUsers parameter in the formAddVpnUsers function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57070Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the gstUp parameter in the guestWifiRuleRefresh function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57069Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the pPppUser parameter in the getsinglepppuser function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57064Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the bindDhcpIndex parameter in the modifyDhcpRule function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57063Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the portMappingIndex parameter in the formDelPortMapping function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57062Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the delDhcpIndex parameter in the formDelDhcpRule function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57061Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain multiple stack overflows in the formIPMacBindModify function via the ruleId, ip, mac, v6 and remark parameters. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57059Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the dhcpIndex parameter in the addDhcpRule function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57058Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain multiple stack overflows in the formSetDebugCfg function via the pEnable, pLevel, and pModule parameters. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 7.5 High severity

    G3 Firmware: Stack-based Buffer Overflow

    CVE-2025-57057Tenda

    Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the listStr parameter in the ipMacBindListStore function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.

  • 8.8 High severity

    AC20: Improper Restriction of Operations within the Bounds of a Memory Buffer

    CVE-2025-10120Tenda

    A vulnerability was detected in Tenda AC20 up to 16.03.08.12. The impacted element is the function strcpy of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in buffer overflow. The attack may be performed from remote. The ex