Vitogate 300 Firmware vulnerabilities
2 known vulnerabilities in Vitogate 300 Firmware from Viessmann. 2 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
2vulnerabilities
2critical
0high
0exploited
9.8average CVSS score
Latest first
- 9.8 Critical severity
Vitogate 300 Firmware: Improper Neutralization of Special Elements used in a Command
In Vitogate 300 2.1.3.0, /cgi-bin/vitogate.cgi allows an unauthenticated attacker to bypass authentication and execute arbitrary commands via shell metacharacters in the ipaddr params JSON data for the put method.
- 9.8 Critical severity
Vitogate 300: Use of Hard-coded Password
A vulnerability classified as critical was found in Viessmann Vitogate 300 up to 2.1.3.0. This vulnerability affects the function isValidUser of the file /cgi-bin/vitogate.cgi of the component Web Management Interface. The manipulation leads to use of hard-cod