CyberSecBulletin
CVE-2022-20918NVD status: Modified

Cisco Firepower Management Center: Improper Authentication

CVE-2022-20918 is a high-severity improper authentication vulnerability in Cisco Firepower Management Center from Cisco, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Cisco Firepower Management Center versions: 7.0.0; 7.0.0.1; 7.0.1, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.04% chance of exploitation within 30 days, higher than 64% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Secure Firewall Management Center to 7.0.5 or a later version.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CiscoCisco Firepower Management Center7.0.0; 7.0.0.1; 7.0.1; 7.0.1.1; 7.0.2; 7.0.2.1; 7.0.3; 7.0.4Not stated
CiscoCisco FirePOWER Services Software for ASANot specified in the recordNot stated
CiscoFirepower Services Software For AsaNot specified in the recordNot stated
CiscoSecure Firewall Management Center7.0.0 up to, but not including, 7.0.57.0.5

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighCNA (cisco.com)
CVSS 3.17.5HighNVD

Official description

A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential. This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential. This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Authentication

When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

How developers prevent this class of flaw

  • Use an authentication framework or library such as the OWASP ESAPI Authentication feature.

More Improper Authentication vulnerabilities (CWE-287)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Cisco Firepower Management Center

All Cisco Firepower Management Center vulnerabilities

Recent Improper Authentication vulnerabilities

Spotted an error? Tell us.