CyberSecBulletin
CVE-2022-24316NVD status: Modified

Interactive Graphical SCADA System Data Server…: Improper Initialization

CVE-2022-24316 is a high-severity improper initialization vulnerability in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior), with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. There is no confirmed exploitation so far. EPSS estimates a 1.27% chance of exploitation within 30 days, higher than 70% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on download.schneider-electric.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighNVD
CVSS 2.05.0MediumNVD

Official description

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Initialization

The product does not initialize or incorrectly initializes a resource.

How developers prevent this class of flaw

  • Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, in Java, if the programmer does not explicitly initialize a variable, then the code could produce a compile-time error (if the variable is local) or automatically initialize the variable to the default value for the variable's type. In Perl, if explicit initialization is not performed, then a default value of undef is assigned, which is interpreted as 0, false, or an equivalent value depending on the context in which the variable is accessed.
  • Identify all variables and data stores that receive information from external sources, and apply input validation to make sure that they are only initialized to expected values.
  • Explicitly initialize all your variables and other data stores, either during declaration or just before the first usage.

More Improper Initialization vulnerabilities (CWE-665)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Other vulnerabilities in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

All Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) vulnerabilities

Recent Improper Initialization vulnerabilities