CVE-2022-24317NVD status: Modified

Interactive Graphical SCADA System Data Server…: Missing Authorization

CVE-2022-24317 is a high-severity missing authorization vulnerability in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior), with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. There is no confirmed exploitation so far. EPSS estimates a 1.21% chance of exploitation within 30 days, higher than 69% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on download.schneider-electric.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighNVD
CVSS 2.05.0MediumNVD

Official description

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Missing Authorization

The product does not perform an authorization check when an actor attempts to access a resource or perform an action.

How developers prevent this class of flaw

  • Divide the product into anonymous, normal, privileged, and administrative areas. Reduce the attack surface by carefully mapping roles with data and functionality. Use role-based access control (RBAC) to enforce the roles at the appropriate boundaries. Note that this approach may not protect against horizontal authorization, i.e., it will not protect a user from attacking others with the same role.
  • Ensure that access control checks are performed related to the business logic. These checks may be different than the access control checks that are applied to more generic resources such as files, connections, processes, memory, and database records. For example, a database may restrict access for medical records to a specific database user, but each record might only be intended to be accessible to the patient and the patient's doctor.
  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using authorization frameworks such as the JAAS Authorization Framework and the OWASP ESAPI Access Control feature.

More Missing Authorization vulnerabilities (CWE-862)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Other vulnerabilities in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

All Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) vulnerabilities

Recent Missing Authorization vulnerabilities

Spotted an error? Tell us.