https://github.com/curl/curl: Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-27775 is a high-severity exposure of sensitive information to an unauthorized actor vulnerability in https://github.com/curl/curl, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected https://github.com/curl/curl versions: curl 7.65.0 to 7.82.0 are vulnerable. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 3.34% chance of exploitation within 30 days, higher than 89% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update SIMATIC S7-1500 CPU 1518-4 PN/DP MFP to V3.1.5 or a later version.
- Update SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP to V3.1.5 or a later version.
- Update SIPLUS S7-1500 CPU 1518-4 PN/DP MFP to V3.1.5 or a later version.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Https://github.com/curl/curl | https://github.com/curl/curl | curl 7.65.0 to 7.82.0 are vulnerable | Not stated |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | V3.1.0 up to, but not including, V3.1.5 | V3.1.5 |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | V3.1.0 up to, but not including, V3.1.5 | V3.1.5 |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | V3.1.0 up to, but not including, V3.1.5 | V3.1.5 |
| Haxx | Curl | 7.65.0 through 7.82.0 | Not stated |
| Debian | Debian Linux | 11.0 | Not stated |
| NetApp | Hci Bootstrap OS | Not specified in the record | Not stated |
| NetApp | Clustered Data Ontap | Not specified in the record | Not stated |
| NetApp | Solidfire & Hci Management Node | Not specified in the record | Not stated |
| NetApp | Solidfire & Hci Storage Node | Not specified in the record | Not stated |
| Broadcom | Fabric Operating System | Not specified in the record | Not stated |
| NetApp | H300s Firmware | Not specified in the record | Not stated |
| NetApp | H500s Firmware | Not specified in the record | Not stated |
| NetApp | H700s Firmware | Not specified in the record | Not stated |
| NetApp | H410s Firmware | Not specified in the record | Not stated |
| Splunk | Universal Forwarder | 8.2.0 up to, but not including, 8.2.12; 9.0.0 up to, but not including, 9.0.6; 9.1.0 | 8.2.12, 9.0.6 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- NoneNothing can be modified.
- Availability
- NoneAvailability is not affected.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 7.5 | High | NVD |
| CVSS 3.1 | 7.5 | High | CISA (ADP) |
| CVSS 2.0 | 5.0 | Medium | NVD |
Official description
An information disclosure vulnerability exists in curl 7.65.0 to 7.82.0 are vulnerable that by using an IPv6 address that was in the connection pool but with a different zone id it could reuse a connection instead.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Exposure of Sensitive Information to an Unauthorized Actor
The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information.
How developers prevent this class of flaw
- Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
More Exposure of Sensitive Information to an Unauthorized Actor vulnerabilities (CWE-200)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- security.gentoo.org/glsa/202212-01Third Party Advisory
- security.netapp.com/advisory/ntap-20220609-0008/Third Party Advisory
- debian.org/security/2022/dsa-5197Third Party Advisory
Technical write-ups (may include proof of concept)
- hackerone.com/reports/1546268Exploit, Third Party Advisory
Other references
Other vulnerabilities in https://github.com/curl/curl
- 7.5 High severity
- 8.8 High severity
- 8.8 High severity
- 9.1 Critical severity
- 7.5 High severity
- 9.8 Critical severity
Recent Exposure of Sensitive Information to an Unauthorized Actor vulnerabilities
- 6.5 Medium severity
Cisco IOS XR Open Port Exploited
- 7.5 High severity
- 7.1 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
Spotted an error? Tell us.