CyberSecBulletin
CVE-2023-0954NVD status: Modified

Illustra Pro Gen 4 Dome: Active Debug Code

CVE-2023-0954 is a critical-severity active debug code vulnerability in Illustra Pro Gen 4 Dome from Sensormatic Electronics, a subsidiary of Johnson Controls, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Illustra Pro Gen 4 Dome versions: Illustra.SS016.05.09.04.0006 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.67% chance of exploitation within 30 days, higher than 53% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of Illustra Pro Gen 4 Dome you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Sensormatic Electronics, a subsidiary of Johnson ControlsIllustra Pro Gen 4 DomeIllustra.SS016.05.09.04.0006 and earlierNot stated
Sensormatic Electronics, a subsidiary of Johnson ControlsIllustra Pro Gen 4 PTZIllustra.SS010.05.09.04.0022 and earlierNot stated
JohnsoncontrolsIllustra Pro Gen 4 Dome Firmwaress016.05.09.04.0006 and earlierNot stated
JohnsoncontrolsIllustra Pro Gen 4 Ptz Firmwaress010.05.09.04.0022 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.3HighCNA (jci.com)
CVSS 3.19.8CriticalNVD

Official description

A debug feature in Sensormatic Electronics Illustra Pro Gen 4 Dome and PTZ cameras allows a user to compromise credentials after a long period of sustained attack.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Active Debug Code

The product is released with debugging code still enabled or active.

How developers prevent this class of flaw

  • Remove debug code before deploying the application.

More Active Debug Code vulnerabilities (CWE-489)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Recent Active Debug Code vulnerabilities

Spotted an error? Tell us.