CyberSecBulletin
CVE-2023-1137NVD status: Modified

InfraSuite Device Master: Insufficiently Protected Credentials

CVE-2023-1137 is a high-severity insufficiently protected credentials vulnerability in InfraSuite Device Master from Delta Electronics, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version 1.0.5 as the first without the flaw, so updating InfraSuite Device Master to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.55% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update InfraSuite Device Master to 1.0.5 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
Delta ElectronicsInfraSuite Device Masterbefore 1.0.51.0.5

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.16.5MediumCNA (hq.dhs.gov)
CVSS 3.18.8HighNVD

Official description

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Insufficiently Protected Credentials

The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

How developers prevent this class of flaw

  • Use an appropriate security mechanism to protect the credentials.
  • Make appropriate use of cryptography to protect the credentials.
  • Use industry standards to protect the credentials (e.g. LDAP, keystore, etc.).

More Insufficiently Protected Credentials vulnerabilities (CWE-522)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in InfraSuite Device Master

All InfraSuite Device Master vulnerabilities

Recent Insufficiently Protected Credentials vulnerabilities

Spotted an error? Tell us.