CyberSecBulletin
CVE-2023-41372NVD status: Modified

ctrlX HMI Web Panel - WR21 (WR2107): Use of Hard-coded Credentials

CVE-2023-41372 is a high-severity use of hard-coded credentials vulnerability in ctrlX HMI Web Panel - WR21 (WR2107) from Rexroth, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. Affected ctrlX HMI Web Panel - WR21 (WR2107) versions: all. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.22% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of ctrlX HMI Web Panel - WR21 (WR2107) you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on psirt.bosch.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
RexrothctrlX HMI Web Panel - WR21 (WR2107)allNot stated
RexrothctrlX HMI Web Panel - WR21 (WR2110)allNot stated
RexrothctrlX HMI Web Panel - WR21 (WR2115)allNot stated
Boschrexrothctrlx_hmi_web_panel_wr2107all versionsNot stated
Boschrexrothctrlx_hmi_web_panel_wr2110all versionsNot stated
Boschrexrothctrlx_hmi_web_panel_wr2115all versionsNot stated
BoschrexrothCtrlx Hmi Web Panel Wr2107 FirmwareNot specified in the recordNot stated
BoschrexrothCtrlx Hmi Web Panel Wr2110 FirmwareNot specified in the recordNot stated
BoschrexrothCtrlx Hmi Web Panel Wr2115 FirmwareNot specified in the recordNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.8HighCNA (bosch.com)
CVSS 3.17.8HighNVD

Official description

The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.

How developers prevent this class of flaw

  • For outbound authentication: store passwords, keys, and other credentials outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible. In Windows environments, the Encrypted File System (EFS) may provide some protection.
  • For inbound authentication: Rather than hard-code a default username and password, key, or other authentication credentials for first time logins, utilize a first login mode that requires the user to enter a unique strong password or key.
  • If the product must contain hard-coded credentials or they cannot be removed, perform access control checks and limit which entities can access the feature that requires the hard-coded credentials. For example, a feature might only be enabled through the system console instead of through a network connection.

More Use of Hard-coded Credentials vulnerabilities (CWE-798)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in ctrlX HMI Web Panel - WR21 (WR2107)

All ctrlX HMI Web Panel - WR21 (WR2107) vulnerabilities

Recent Use of Hard-coded Credentials vulnerabilities

Spotted an error? Tell us.