AXIOM: Improper Neutralization of Special Elements used in a Command
CVE-2023-42128 is a high-severity improper neutralization of special elements used in a command vulnerability in AXIOM from Magnet Forensics, with a CVSS 3.0 base score of 8.0 out of 10. It can be exploited from the same local network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected AXIOM versions: 7.4.0.36841. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.89% chance of exploitation within 30 days, higher than 60% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of AXIOM you run against the affected versions below, and install the vendor's latest release.
- Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Magnet Forensics | AXIOM | 7.4.0.36841 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- AdjacentThe attacker must be on the same local network segment.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- RequiredA user must take an action such as opening a file or link.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (trendmicro.com).
Official description
Magnet Forensics AXIOM Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Magnet Forensics AXIOM. User interaction is required to exploit this vulnerability in that the target must acquire data from a malicious mobile device. The specific flaw exists within the Android device image acquisition functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-21255.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- zerodayinitiative.com/advisories/ZDI-23-1533/Third Party Advisory
Other vulnerabilities in AXIOM
- 8.0 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.8 High severity
- 8.8 High severity
- 9.8 Critical severity
- 7.5 High severity
- 10.0 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.