CyberSecBulletin
CVE-2024-7448NVD status: Analyzed

AXIOM: Improper Neutralization of Special Elements used in an OS Command

CVE-2024-7448 is a high-severity improper neutralization of special elements used in an OS command vulnerability in AXIOM from Magnet Forensics, with a CVSS 3.1 base score of 8.0 out of 10. It can be exploited from the same local network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected AXIOM versions: 8.0.0.39753. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.71% chance of exploitation within 30 days, higher than 78% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of AXIOM you run against the affected versions below, and install the vendor's latest release.
  2. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
Magnet ForensicsAXIOM8.0.0.39753Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.0HighNVD
CVSS 3.08.0HighCNA (trendmicro.com)

Official description

Magnet Forensics AXIOM Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Magnet Forensics AXIOM. User interaction is required to exploit this vulnerability in that the target must acquire data from a malicious mobile device. The specific flaw exists within the Android device image acquisition functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-23964.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).