CyberSecBulletin
CVE-2024-23786NVD status: Modified

Energy Management Controller with Cloud Services: Improper Neutralization of Input During Web Page Generation

CVE-2024-23786 is a critical-severity improper neutralization of input during web page generation vulnerability in Energy Management Controller with Cloud Services from Sharp, with a CVSS 3.1 base score of 9.3 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Energy Management Controller with Cloud Services versions: JH-RVB1 Ver.B0.1.9.1 and earlier; JH-RV11 Ver.B0.1.9.1 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.79% chance of exploitation within 30 days, higher than 57% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of Energy Management Controller with Cloud Services you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on jp.sharp for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  4. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SHARPEnergy Management Controller with Cloud ServicesJH-RVB1 Ver.B0.1.9.1 and earlier; JH-RV11 Ver.B0.1.9.1 and earlierNot stated
SharpJh-rvb1 Firmwareb0.1.9.1 and earlierNot stated
SharpJh-rv11 Firmwareb0.1.9.1 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.3CriticalNVD
CVSS 3.19.3CriticalCISA (ADP)

Official description

Cross-site scripting vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary script on the web browser of the user who is accessing the management page of the affected product.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Input During Web Page Generation

The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

How developers prevent this class of flaw

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Examples of libraries and frameworks that make it easier to generate properly encoded output include Microsoft's Anti-XSS library, the OWASP ESAPI Encoding module, and Apache Wicket.
  • Understand all the potential areas where untrusted inputs can enter your software: parameters or arguments, cookies, anything read from the network, environment variables, reverse DNS lookups, query results, request headers, URL components, e-mail, files, filenames, databases, and any external systems that provide data to the application. Remember that such inputs may be obtained indirectly through API calls.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Input During Web Page Generation vulnerabilities (CWE-79)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in Energy Management Controller with Cloud Services

All Energy Management Controller with Cloud Services vulnerabilities

Recent Improper Neutralization of Input During Web Page Generation vulnerabilities

Spotted an error? Tell us.