CyberSecBulletin
CVE-2024-23789NVD status: Analyzed

Energy Management Controller with Cloud Services: Improper Neutralization of Special Elements used in an OS Command

CVE-2024-23789 is a high-severity improper neutralization of special elements used in an OS command vulnerability in Energy Management Controller with Cloud Services from Sharp, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. Affected Energy Management Controller with Cloud Services versions: JH-RVB1 Ver.B0.1.9.1 and earlier; JH-RV11 Ver.B0.1.9.1 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.18% chance of exploitation within 30 days, higher than 68% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Energy Management Controller with Cloud Services you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on jp.sharp for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
SHARPEnergy Management Controller with Cloud ServicesJH-RVB1 Ver.B0.1.9.1 and earlier; JH-RV11 Ver.B0.1.9.1 and earlierNot stated
Sharp Corporationenergy_management_controller_with_cloud_services_\(jh-rvb1\)b0.1.9.1 and earlierNot stated
Sharp Corporationenergy_management_controller_with_cloud_services_\(jh-rv11\)b0.1.9.1 and earlierNot stated
SharpJh-rvb1 Firmwareb0.1.9.1 and earlierNot stated
SharpJh-rv11 Firmwareb0.1.9.1 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.8HighNVD
CVSS 3.19.8CriticalCISA (ADP)

Official description

Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command on the affected product.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in Energy Management Controller with Cloud Services

All Energy Management Controller with Cloud Services vulnerabilities

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.