CyberSecBulletin
CVE-2024-29082NVD status: Analyzed

VAR1200-H: Improper Access Control

CVE-2024-29082 is a high-severity improper access control vulnerability in VAR1200-H from Vonets, with a CVSS 3.1 base score of 8.6 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected VAR1200-H versions: 3.3.23.6.9 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.8% chance of exploitation within 30 days, higher than 57% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of VAR1200-H you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
VonetsVAR1200-H3.3.23.6.9 and earlierNot stated
VonetsVAR1200-L3.3.23.6.9 and earlierNot stated
VonetsVAR600-H3.3.23.6.9 and earlierNot stated
VonetsVAP11AC3.3.23.6.9 and earlierNot stated
VonetsVAP11G-500S3.3.23.6.9 and earlierNot stated
VonetsVBG12003.3.23.6.9 and earlierNot stated
VonetsVAP11S-5G3.3.23.6.9 and earlierNot stated
VonetsVAP11S3.3.23.6.9 and earlierNot stated
VonetsVAR11N-3003.3.23.6.9 and earlierNot stated
VonetsVAP11G-3003.3.23.6.9 and earlierNot stated
VonetsVAP11N-3003.3.23.6.9 and earlierNot stated
VonetsVAP11G3.3.23.6.9 and earlierNot stated
VonetsVAP11G-5003.3.23.6.9 and earlierNot stated
VonetsVGA-10003.3.23.6.9 and earlierNot stated
Vonetsvar1200-h_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar1200-l_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar600-h_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11ac_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11g-500s_firmware3.3.23.6.9 and earlierNot stated
Vonetsvbg1200_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11s-5g_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11s_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar11n-300_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11n-300_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11g_firmware3.3.23.6.9 and earlierNot stated

Version data comes from the organisation that assigned the CVE; 3 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
LowSome restricted data can be read.
Integrity
LowLimited modification of data is possible.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.08.8HighCNA (hq.dhs.gov)
CVSS 3.18.6HighCNA (hq.dhs.gov)
CVSS 3.18.6HighNVD

Official description

Improper access control vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Improper Access Control vulnerabilities (CWE-284)

Timeline

  1. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  2. CVE record published.
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in VAR1200-H

All VAR1200-H vulnerabilities

Recent Improper Access Control vulnerabilities

Spotted an error? Tell us.