CVE-2024-41161NVD status: Analyzed

VAR1200-H: Use of Hard-coded Credentials

CVE-2024-41161 is a critical-severity use of hard-coded credentials vulnerability in VAR1200-H from Vonets, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected VAR1200-H versions: 3.3.23.6.9 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.63% chance of exploitation within 30 days, higher than 51% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of VAR1200-H you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
VonetsVAR1200-H3.3.23.6.9 and earlierNot stated
VonetsVAR1200-L3.3.23.6.9 and earlierNot stated
VonetsVAR600-H3.3.23.6.9 and earlierNot stated
VonetsVAP11AC3.3.23.6.9 and earlierNot stated
VonetsVAP11G-500S3.3.23.6.9 and earlierNot stated
VonetsVBG12003.3.23.6.9 and earlierNot stated
VonetsVAP11S-5G3.3.23.6.9 and earlierNot stated
VonetsVAP11S3.3.23.6.9 and earlierNot stated
VonetsVAR11N-3003.3.23.6.9 and earlierNot stated
VonetsVAP11G-3003.3.23.6.9 and earlierNot stated
VonetsVAP11N-3003.3.23.6.9 and earlierNot stated
VonetsVAP11G3.3.23.6.9 and earlierNot stated
VonetsVAP11G-5003.3.23.6.9 and earlierNot stated
VonetsVGA-10003.3.23.6.9 and earlierNot stated
Vonetsvar1200-h_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar1200-l_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar600-h_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11ac_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11g-500s_firmware3.3.23.6.9 and earlierNot stated
Vonetsvbg1200_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11s-5g_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11s_firmware3.3.23.6.9 and earlierNot stated
Vonetsvar11n-300_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11n-300_firmware3.3.23.6.9 and earlierNot stated
Vonetsvap11g_firmware3.3.23.6.9 and earlierNot stated

Version data comes from the organisation that assigned the CVE; 3 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.08.7HighCNA (hq.dhs.gov)
CVSS 3.17.5HighCNA (hq.dhs.gov)
CVSS 3.19.8CriticalNVD

Official description

Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication using hard-coded administrator credentials. These accounts cannot be disabled.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.

How developers prevent this class of flaw

  • For outbound authentication: store passwords, keys, and other credentials outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible. In Windows environments, the Encrypted File System (EFS) may provide some protection.
  • For inbound authentication: Rather than hard-code a default username and password, key, or other authentication credentials for first time logins, utilize a first login mode that requires the user to enter a unique strong password or key.
  • If the product must contain hard-coded credentials or they cannot be removed, perform access control checks and limit which entities can access the feature that requires the hard-coded credentials. For example, a feature might only be enabled through the system console instead of through a network connection.

More Use of Hard-coded Credentials vulnerabilities (CWE-798)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in VAR1200-H

All VAR1200-H vulnerabilities

Recent Use of Hard-coded Credentials vulnerabilities

Spotted an error? Tell us.