Computer Laboratory Management System: Always-Incorrect Control Flow Implementation
CVE-2024-3376 is a critical-severity always-incorrect control flow implementation vulnerability in Computer Laboratory Management System from SourceCodester, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Computer Laboratory Management System versions: 1.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.34% chance of exploitation within 30 days, higher than 72% of scored CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of Computer Laboratory Management System you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| SourceCodester | Computer Laboratory Management System | 1.0 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 7.3 | High | CNA (vuldb.com) |
| CVSS 3.1 | 9.8 | Critical | NVD |
| CVSS 2.0 | 7.5 | High | CNA (vuldb.com) |
Official description
A vulnerability classified as critical has been found in SourceCodester Computer Laboratory Management System 1.0. This affects an unknown part of the file config.php. The manipulation of the argument url leads to execution after redirect. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-259497 was assigned to this vulnerability.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Always-Incorrect Control Flow Implementation
The code contains a control flow path that does not reflect the algorithm that the path is intended to implement, leading to incorrect behavior any time this path is navigated.
More Always-Incorrect Control Flow Implementation vulnerabilities (CWE-670)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- vuldb.com/?id.259497Third Party Advisory
- vuldb.com/?submit.311154Third Party Advisory
Technical write-ups (may include proof of concept)
- github.com/Sospiro014/zday1/blob/main/Execution_After_Redirect.mdExploit, Third Party Advisory
Other references
- vuldb.com/?ctiid.259497Permissions Required
Other vulnerabilities in Computer Laboratory Management System
- 8.8 High severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 7.3 High severity
Recent Always-Incorrect Control Flow Implementation vulnerabilities
- 7.5 High severity
- 9.8 Critical severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
Spotted an error? Tell us.