IndraDrive FWA-INDRV*-MP*: Uncontrolled Resource Consumption
CVE-2024-48989 is a high-severity uncontrolled resource consumption vulnerability in IndraDrive FWA-INDRV*-MP* from Bosch Rexroth, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 20V36 as the first without the flaw, so updating IndraDrive FWA-INDRV*-MP* to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.49% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update IndraDrive FWA-INDRV*-MP* to 20V36 or a later version.
- Update indradrive_fwa_indrv_mp to 20v36 or a later version.
- Read the advisory on psirt.bosch.com for workarounds and exact fixed builds.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Bosch Rexroth | IndraDrive FWA-INDRV*-MP* | 17VRS up to, but not including, 20V36 | 20V36 |
| Boschrexrothag | indradrive_fwa_indrv_mp | 17vrs up to, but not including, 20v36 | 20v36 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- NoneNo data is disclosed.
- Integrity
- NoneNothing can be modified.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by CNA (bosch.com).
Official description
A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Uncontrolled Resource Consumption
The product does not properly control the allocation and maintenance of a limited resource.
How developers prevent this class of flaw
- Ensure that protocols have specific limits of scale placed on them.
- Ensure that all failures in resource allocation place the system into a safe posture.
More Uncontrolled Resource Consumption vulnerabilities (CWE-400)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Recent Uncontrolled Resource Consumption vulnerabilities
- 7.5 High severity
- 7.5 High severity
- 8.7 High severity
- 8.7 High severity
- 8.7 High severity
- 7.5 High severity
Spotted an error? Tell us.