CyberSecBulletin
CVE-2025-30047NVD status: Deferred

CGM CLININET: Deserialization of Untrusted Data

CVE-2025-30047 is a critical-severity deserialization of untrusted data vulnerability in CGM CLININET from CGM, with a CVSS 4.0 base score of 9.4 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists version 2026.MS3 as the first without the flaw, so updating CGM CLININET to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.38% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update CGM CLININET to 2026.MS3 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
CGMCGM CLININETbefore 2026.MS32026.MS3

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
HighSerious loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
HighSerious loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (cert.pl).

Official description

CGM CLININET is vulnerable to Remote Code Execution caused by deserialization of untrusted data. The server exposes an HTTP-based API, used by the administrative module, that exchanges data using Java object serialization. An attacker within the same local network is able to send requests to this API and transmit a crafted serialized object. When it is deserialized, it allows arbitrary code execution with root privileges on the server. This issue was fixed in version 2026.MS3

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Deserialization of Untrusted Data

The product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid.

How developers prevent this class of flaw

  • If available, use the signing/sealing features of the programming language to assure that deserialized data has not been tainted. For example, a hash-based message authentication code (HMAC) could be used to ensure that data has not been modified.
  • When deserializing data, populate a new object rather than just deserializing. The result is that the data flows through safe input validation and that the functions are safe.
  • Explicitly define a final object() to prevent deserialization.

More Deserialization of Untrusted Data vulnerabilities (CWE-502)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in CGM CLININET

All CGM CLININET vulnerabilities

Recent Deserialization of Untrusted Data vulnerabilities