CVE-2025-30052NVD status: Deferred

CGM CLININET: Authentication Bypass by Spoofing

CVE-2025-30052 is a high-severity authentication bypass by spoofing vulnerability in CGM CLININET from CGM, with a CVSS 4.0 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected CGM CLININET versions: 2026.MS3 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.34% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of CGM CLININET you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CGMCGM CLININET2026.MS3 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
NoneNo loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
NoneNo loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
LowLimited loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
NoneNo loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (cert.pl).

Official description

The rsyncd service of the CGM CLININET is vulnerable to Authentication Bypass via IP spoofing. Access is granted based solely on the client's source IP address. An attacker able to spoof an allowed IP address, can bypass this check and gain the ability to edit files on the affected system. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Authentication Bypass by Spoofing

This attack-focused weakness is caused by incorrectly implemented authentication schemes that are subject to spoofing attacks.

More Authentication Bypass by Spoofing vulnerabilities (CWE-290)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).