CyberSecBulletin
CVE-2025-50123NVD status: Deferred

EcoStruxure™ IT Data Center Expert: Improper Control of Generation of Code

CVE-2025-50123 is a high-severity improper control of generation of code vulnerability in EcoStruxure™ IT Data Center Expert from Schneider Electric, with a CVSS 4.0 base score of 7.2 out of 10. It can be exploited with physical access to the device by an attacker with administrator privileges, without any action from a user. Affected EcoStruxure™ IT Data Center Expert versions: 8.3 through Prior to. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.38% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of EcoStruxure™ IT Data Center Expert you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
Schneider ElectricEcoStruxure™ IT Data Center Expert8.3 through Prior toNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
PhysicalThe attacker must physically touch the device.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
PresentThe target must be in a specific state or configuration for the attack to work.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
HighSerious loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
LowLimited loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (se.com).

Official description

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote command execution by a privileged account when the server is accessed via a console and through exploitation of the hostname input.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Control of Generation of Code

The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.

How developers prevent this class of flaw

  • Refactor your program so that you do not have to dynamically generate code.
  • Run your code in a jail or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which code can be executed by your product. Examples include the Unix chroot jail and AppArmor. In general, managed code may provide some protection. This may not be a feasible solution, and it only limits the impact to the operating system; the rest of your application may still be subject to compromise. Be careful to avoid CWE-243 and other weaknesses related to jails.
  • Use dynamic tools and techniques that interact with the product using large test suites with many diverse inputs, such as fuzz testing (fuzzing), robustness testing, and fault injection. The product's operation may slow down, but it should not become unstable, crash, or generate incorrect results.

More Improper Control of Generation of Code vulnerabilities (CWE-94)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).