CyberSecBulletin
CVE-2025-50124NVD status: Deferred

EcoStruxure™ IT Data Center Expert: Improper Privilege Management

CVE-2025-50124 is a high-severity improper privilege management vulnerability in EcoStruxure™ IT Data Center Expert from Schneider Electric, with a CVSS 4.0 base score of 7.2 out of 10. It can be exploited with physical access to the device by an attacker with administrator privileges, without any action from a user. Affected EcoStruxure™ IT Data Center Expert versions: 8.3 through Prior to. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.21% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of EcoStruxure™ IT Data Center Expert you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
Schneider ElectricEcoStruxure™ IT Data Center Expert8.3 through Prior toNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
PhysicalThe attacker must physically touch the device.
Attack complexity
HighSuccess depends on conditions outside the attacker's control.
Attack requirements
PresentThe target must be in a specific state or configuration for the attack to work.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
HighSerious loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
LowLimited loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (se.com).

Official description

A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a console and through exploitation of a setup script.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Privilege Management

The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Follow the principle of least privilege when assigning access rights to entities in a software system.
  • Consider following the principle of separation of privilege. Require multiple conditions to be met before permitting access to a system resource.

More Improper Privilege Management vulnerabilities (CWE-269)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in EcoStruxure™ IT Data Center Expert

All EcoStruxure™ IT Data Center Expert vulnerabilities

Recent Improper Privilege Management vulnerabilities

Spotted an error? Tell us.