CyberSecBulletin
CVE-2025-54808NVD status: Deferred

MinKNOW: Insufficiently Protected Credentials

CVE-2025-54808 is a high-severity insufficiently protected credentials vulnerability in MinKNOW from Oxford Nanopore Technologies, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 24.11 as the first without the flaw, so updating MinKNOW to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.16% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update MinKNOW to 24.11 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
Oxford Nanopore TechnologiesMinKNOWbefore 24.1124.11

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (hq.dhs.gov).

Scoring systemScoreSeverityScored by
CVSS 4.07.3HighCNA (hq.dhs.gov)
CVSS 3.17.8HighCNA (hq.dhs.gov)

Official description

Oxford Nanopore Technologies' MinKNOW software at or prior to version 24.11 stores authentication tokens in a file located in the system's temporary directory (/tmp) on the host machine. This directory is typically world-readable, allowing any local user or application to access the token. If the token is leaked (e.g., via malware infection or other local exploit), and remote access is enabled, it can be used to establish unauthorized remote connections to the sequencer. Remote access must be enabled for remote exploitation to succeed. This may occur either because the user has enabled remote access for legitimate operational reasons or because malware with elevated privileges (e.g., sudo access) enables it without user consent. This vulnerability can be chained with remote access capabilities to generate a developer token from a remote device. Developer tokens can be created with arbitrary expiration dates, enabling persistent access to the sequencer and bypassing standard authentication mechanisms.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Insufficiently Protected Credentials

The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

How developers prevent this class of flaw

  • Use an appropriate security mechanism to protect the credentials.
  • Make appropriate use of cryptography to protect the credentials.
  • Use industry standards to protect the credentials (e.g. LDAP, keystore, etc.).

More Insufficiently Protected Credentials vulnerabilities (CWE-522)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Insufficiently Protected Credentials vulnerabilities

Spotted an error? Tell us.