CyberSecBulletin
CVE-2025-5825NVD status: Analyzed

Autel MaxiCharger AC Wallbox Commercial: Security Version Number Mutable to Older Versions

CVE-2025-5825 is a high-severity security version number mutable to older versions vulnerability in Autel MaxiCharger AC Wallbox Commercial from Autel, with a CVSS 3.0 base score of 7.5 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. Affected Autel MaxiCharger AC Wallbox Commercial versions: 1.36.00. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.28% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Maxicharger Ac Elite Business C50 Firmware to 1.39.51 or 1.56.51, whichever matches your release line, or a later version.
  2. Update Maxicharger Ac Pro Firmware to 1.39.51 or 1.56.51, whichever matches your release line, or a later version.
  3. Update Maxicharger Ac Ultra Firmware to 1.39.51 or 1.56.51, whichever matches your release line, or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
AutelAutel MaxiCharger AC Wallbox Commercial1.36.00Not stated
AutelMaxicharger Ac Elite Business C50 Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Ac Pro Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Ac Ultra Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Dc Compact Mobile Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Dc Compact Pedestal Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Dc Fast Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Dc Hipower Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Dh480 Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51
AutelMaxicharger Single Charger Firmwarebefore 1.39.51; before 1.56.511.39.51, 1.56.51

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
HighSuccess depends on conditions outside the attacker's control.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (trendmicro.com).

Official description

Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Security Version Number Mutable to Older Versions

The security version number in the hardware product is mutable, resulting in the ability to downgrade (roll-back) the boot firmware to vulnerable code versions.

How developers prevent this class of flaw

  • The security version number must be stored securely and persistently across power-on resets. When architecting the system, security version data should be designated for storage in registers that are either read-only or have access controls that prevent modification by an untrusted agent.
  • During implementation and test, security version data should be demonstrated to be read-only and access controls should be validated.

More Security Version Number Mutable to Older Versions vulnerabilities (CWE-1328)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in Autel MaxiCharger AC Wallbox Commercial

All Autel MaxiCharger AC Wallbox Commercial vulnerabilities

Spotted an error? Tell us.