Azure Web Apps: Improper Neutralization of Special Elements used in a Command
CVE-2026-119989 is a high-severity improper neutralization of special elements used in a command vulnerability in Azure Web Apps from Microsoft, with a CVSS 3.1 base score of 8.2 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version 2.10.0 as the first without the flaw, so updating Azure Web Apps to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.59% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Azure Web Apps to 2.10.0 or a later version.
- Read the advisory on msrc.microsoft.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Microsoft | Azure Web Apps | 1.0.0 up to, but not including, 2.10.0 | 2.10.0 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- HighSuccess depends on conditions outside the attacker's control.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- NoneAvailability is not affected.
Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N. Scored by CNA (microsoft.com).
Official description
Improper neutralization of special elements used in a command ('command injection') in Azure Pipelines allows an authorized attacker to execute code over a network.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).