Windows 10 Version 1607: Improper Neutralization of Special Elements used in a Command
CVE-2026-96053 is a high-severity improper neutralization of special elements used in a command vulnerability in Windows 10 Version 1607 from Microsoft, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 10.0.14393.9688 as the first without the flaw, so updating Windows 10 Version 1607 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.73% chance of exploitation within 30 days, higher than 55% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Windows 10 Version 1607 to 10.0.14393.9688 or a later version.
- Update Windows 10 Version 1809 to 10.0.17763.9487 or a later version.
- Update Windows 10 Version 21H2 to 10.0.19044.7846 or a later version.
- Read the advisory on msrc.microsoft.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Microsoft | Windows 10 Version 1607 | 10.0.14393.0 up to, but not including, 10.0.14393.9688 | 10.0.14393.9688 |
| Microsoft | Windows 10 Version 1809 | 10.0.17763.0 up to, but not including, 10.0.17763.9487 | 10.0.17763.9487 |
| Microsoft | Windows 10 Version 21H2 | 10.0.19044.0 up to, but not including, 10.0.19044.7846 | 10.0.19044.7846 |
| Microsoft | Windows 10 Version 22H2 | 10.0.19045.0 up to, but not including, 10.0.19045.7846 | 10.0.19045.7846 |
| Microsoft | Windows 11 version 23H2 | 10.0.22631.0 up to, but not including, 10.0.22631.7711 | 10.0.22631.7711 |
| Microsoft | Windows 11 Version 24H2 | 10.0.26100.0 up to, but not including, 10.0.26100.9974 | 10.0.26100.9974 |
| Microsoft | Windows 11 Version 25H2 | 10.0.26200.0 up to, but not including, 10.0.26200.9974 | 10.0.26200.9974 |
| Microsoft | Windows 11 version 26H1 | 10.0.28000.0 up to, but not including, 10.0.28000.3501 | 10.0.28000.3501 |
| Microsoft | Windows 11 Version 26H2 | 10.0.26300.0 up to, but not including, 10.0.26300.9974 | 10.0.26300.9974 |
| Microsoft | Windows Server 2016 | 10.0.14393.0 up to, but not including, 10.0.14393.9688 | 10.0.14393.9688 |
| Microsoft | Windows Server 2016 (Server Core installation) | 10.0.14393.0 up to, but not including, 10.0.14393.9688 | 10.0.14393.9688 |
| Microsoft | Windows Server 2019 | 10.0.17763.0 up to, but not including, 10.0.17763.9487 | 10.0.17763.9487 |
| Microsoft | Windows Server 2019 (Server Core installation) | 10.0.17763.0 up to, but not including, 10.0.17763.9487 | 10.0.17763.9487 |
| Microsoft | Windows Server 2022 | 10.0.20348.0 up to, but not including, 10.0.20348.5870 | 10.0.20348.5870 |
| Microsoft | Windows Server 2025 | 10.0.26100.0 up to, but not including, 10.0.26100.33822 | 10.0.26100.33822 |
| Microsoft | Windows Server 2025 (Server Core installation) | 10.0.26100.0 up to, but not including, 10.0.26100.33822 | 10.0.26100.33822 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (microsoft.com).
Official description
Improper neutralization of special elements used in a command ('command injection') in Windows Task Scheduler allows an authorized attacker to elevate privileges locally.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.0 High severity
- 8.6 High severity
- 8.2 High severity
- 8.8 High severity
- 8.8 High severity
- 8.0 High severity
Spotted an error? Tell us.