CyberSecBulletin
CVE-2026-22105NVD status: Deferred

Delta UFC500: Use of Default Credentials

CVE-2026-22105 is a high-severity use of default credentials vulnerability in Delta UFC500 from Delta Electronics, with a CVSS 4.0 base score of 8.7 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists versions 2.4.18, 4.4.1 as the first without the flaw, so updating Delta UFC500 to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.19% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Delta UFC500 to 2.4.18 or 4.4.1, whichever matches your release line, or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
Delta ElectronicsDelta UFC500before 2.4.18; before 4.4.12.4.18, 4.4.1

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
LowLimited loss of availability on the vulnerable system.
Confidentiality (other systems)
NoneNo loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
NoneNo loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
NoneNo loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (divd.nl).

Official description

Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace, and log in to read and change sensitive settings such as the OCPP backend.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Default Credentials

The product uses default credentials (such as passwords or cryptographic keys) for potentially critical functionality.

How developers prevent this class of flaw

  • Prohibit use of default, hard-coded, or other values that do not vary for each installation of the product - especially for separate organizations.
  • Force the administrator to change the credential upon installation.
  • The product administrator could change the defaults upon installation or during operation.

More Use of Default Credentials vulnerabilities (CWE-1392)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).

References

Other vulnerabilities in Delta UFC500

All Delta UFC500 vulnerabilities

Recent Use of Default Credentials vulnerabilities

Spotted an error? Tell us.