CVE-2026-27662NVD status: Awaiting Analysis

SIMATIC HMI MTP1000 Unified Comfort Panel: Initialization of a Resource with an Insecure Default

CVE-2026-27662 is a high-severity initialization of a resource with an insecure default vulnerability in SIMATIC HMI MTP1000 Unified Comfort Panel from Siemens, with a CVSS 3.1 base score of 7.7 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, without any action from a user. The record lists version V21 as the first without the flaw, so updating SIMATIC HMI MTP1000 Unified Comfort Panel to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.11% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update SIMATIC HMI MTP1000 Unified Comfort Panel to V21 or a later version.
  2. Update SIMATIC HMI MTP1000 Unified Comfort Panel hygienic to V21 or a later version.
  3. Update SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design to V21 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSIMATIC HMI MTP1000 Unified Comfort Panelbefore V21V21
SiemensSIMATIC HMI MTP1000 Unified Comfort Panel hygienicbefore V21V21
SiemensSIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral designbefore V21V21
SiemensSIMATIC HMI MTP1000, Unified Comfort Panel neutralbefore V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)before V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unitbefore V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)before V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)before V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensiobefore V21V21
SiemensSIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top)before V21V21
SiemensSIMATIC HMI MTP1200 Unified Comfort Panelbefore V21V21
SiemensSIMATIC HMI MTP1200 Unified Comfort Panel hygienicbefore V21V21
SiemensSIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral designbefore V21V21
SiemensSIMATIC HMI MTP1200 Unified Comfort Panel neutral designbefore V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom)before V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unitbefore V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top)before V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom)before V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensiobefore V21V21
SiemensSIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top)before V21V21
SiemensSIMATIC HMI MTP1500 Unified Comfort Panelbefore V21V21
SiemensSIMATIC HMI MTP1500 Unified Comfort Panel hygienicbefore V21V21
SiemensSIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral designbefore V21V21
SiemensSIMATIC HMI MTP1500 Unified Comfort Panel neutral designbefore V21V21
SiemensSIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom)before V21V21

Version data comes from the organisation that assigned the CVE; 25 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H. Scored by CNA (siemens.com).

Scoring systemScoreSeverityScored by
CVSS 4.07.0HighCNA (siemens.com)
CVSS 3.17.7HighCNA (siemens.com)

Official description

Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place. This could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Initialization of a Resource with an Insecure Default

The product initializes or sets a resource with a default that is intended to be changed by the product's installer, administrator, or maintainer, but the default is not secure.

More Initialization of a Resource with an Insecure Default vulnerabilities (CWE-1188)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SIMATIC HMI MTP1000 Unified Comfort Panel

All SIMATIC HMI MTP1000 Unified Comfort Panel vulnerabilities

Recent Initialization of a Resource with an Insecure Default vulnerabilities

Spotted an error? Tell us.