incus: Improper Neutralization of Special Elements Used in a Template Engine
CVE-2026-33897 is a critical-severity improper neutralization of special elements used in a template engine vulnerability in incus from Lxc, with a CVSS 3.1 base score of 9.9 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected incus versions: < 6.23.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.5% chance of exploitation within 30 days, which is low compared with other CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of incus you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on github.com for workarounds and exact fixed builds.
Affected products and versions
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H. Scored by CNA (github.com).
Official description
Incus is a system container and virtual machine manager. Prior to version 6.23.0, instance template files can be used to cause arbitrary read or writes as root on the host server. Incus allows for pongo2 templates within instances which can be used at various times in the instance lifecycle to template files inside of the instance. This particular implementation of pongo2 within Incus allowed for file read/write but with the expectation that the pongo2 chroot feature would isolate all such access to the instance's filesystem. This was allowed such that a template could theoretically read a file and then generate a new version of said file. Unfortunately the chroot isolation mechanism is entirely skipped by pongo2 leading to easy access to the entire system's filesystem with root privileges. Version 6.23.0 patches the issue.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements Used in a Template Engine
The product uses a template engine to insert or process externally-influenced input, but it does not neutralize or incorrectly neutralizes special elements or syntax that can be interpreted as template expressions or other code directives when processed by the engine.
How developers prevent this class of flaw
- Choose a template engine that offers a sandbox or restricted mode, or at least limits the power of any available expressions, function calls, or commands.
- Use the template engine's sandbox or restricted mode, if available.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in incus
- 9.9 Critical severity
- 7.7 High severity
- 9.9 Critical severity
- 7.1 High severity
- 8.5 High severity
- 7.1 High severity
Recent Improper Neutralization of Special Elements Used in a Template Engine vulnerabilities
- 8.5 High severity
- 7.2 High severity
- 9.1 Critical severity
- 7.2 High severity
- 7.7 High severity
- 8.8 High severity
Spotted an error? Tell us.