UniFi Network Application: Improper Access Control
CVE-2026-77541 is a critical-severity improper access control vulnerability in UniFi Network Application from Ubiquiti, with a CVSS 3.1 base score of 9.1 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. The record lists version 10.5.67 as the first without the flaw, so updating UniFi Network Application to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.46% chance of exploitation within 30 days, which is low compared with other CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Update UniFi Network Application to 10.5.67 or a later version.
- Read the advisory on community.ui.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Ubiquiti | UniFi Network Application | before 10.5.67 | 10.5.67 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. Scored by CNA.
Official description
A malicious actor with access to the network and high privileges could exploit an Improper Access Control vulnerability found in UniFi Network Application to escalate privileges within the UniFi Network Application.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Access Control
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
How developers prevent this class of flaw
- Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
- Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Other vulnerabilities in UniFi Network Application
- 9.1 Critical severity
- 7.5 High severity
- 8.3 High severity
- 8.8 High severity
- 8.7 High severity
- 7.5 High severity
Recent Improper Access Control vulnerabilities
- 9.8 Critical severity
- 9.9 Critical severity
- 9.0 Critical severity
- 8.2 High severity
- 9.9 Critical severity
- 9.9 Critical severity
Spotted an error? Tell us.