CyberSecBulletin
CVE-2026-77551NVD status: Deferred

UniFi Connect Display Cast Pro: Improper Access Control

CVE-2026-77551 is a critical-severity improper access control vulnerability in UniFi Connect Display Cast Pro from Ubiquiti, with a CVSS 3.1 base score of 9.0 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 1.0.111 as the first without the flaw, so updating UniFi Connect Display Cast Pro to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.37% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update UniFi Connect Display Cast Pro to 1.0.111 or a later version.
  2. Read the advisory on community.ui.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
UbiquitiUniFi Connect Display Cast Probefore 1.0.1111.0.111

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
HighSuccess depends on conditions outside the attacker's control.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H. Scored by CNA.

Official description

A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Improper Access Control vulnerabilities (CWE-284)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in UniFi Connect Display Cast Pro

All UniFi Connect Display Cast Pro vulnerabilities

Recent Improper Access Control vulnerabilities

Spotted an error? Tell us.