8 known vulnerabilities in Vigor2960 Firmware from DrayTek. 8 are rated high or critical, and 3 have been exploited in real attacks. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 9.8 Critical severity
DrayTek Vigor Routers OS Command Injection Exploited
A vulnerability, which was classified as critical, was found in DrayTek Vigor2960 and Vigor300B 1.5.1.4. Affected is an unknown function of the file /cgi-bin/mainfunction.cgi/apmcfgupload of the component Web Management Interface. The manipulation of the argum
- 9.8 Critical severity
Vigor2960: Improper Neutralization of Special Elements used in a Command
A vulnerability, which was classified as critical, has been found in DrayTek Vigor2960 and Vigor300B 1.5.1.3/1.5.1.4. This issue affects some unknown processing of the file /cgi-bin/mainfunction.cgi/apmcfgupptim of the component Web Management Interface. The m
- 8.0 High severity
vigor2960_firmware: Improper Neutralization of Special Elements used in an OS Command
An authorized RCE vulnerability exists in the DrayTek Vigor2960 router version 1.4.4, where an attacker can place a malicious command into the table parameter of the doPPPoE function in the cgi-bin/mainfunction.cgi route, and finally the command is executed by
- 8.0 High severity
vigor3900_firmware: Improper Neutralization of Special Elements used in a Command
DrayTek Vigor 3900 before v1.5.1.5_Beta, DrayTek Vigor 2960 before v1.5.1.5_Beta and DrayTek Vigor 300B before v1.5.1.5_Beta were discovered to contain a command injection vulnerability via the action parameter at cgi-bin/mainfunction.cgi.
- 8.1 High severity
Vigor2960: Improper Limitation of a Pathname to a Restricted Directory
** UNSUPPORTED WHEN ASSIGNED ** Draytek Vigor2960 v1.5.1.4 and v1.5.1.5 are vulnerable to directory traversal via the mainfunction.cgi dumpSyslog 'option' parameter allowing an authenticated attacker with access to the web management interface to delete arbitr
- 7.8 High severity
vigor2960_firmware: Improper Neutralization of Special Elements used in a Command
DrayTek Vigor2960 v1.5.1.4 allows an authenticated attacker with network access to the web management interface to inject operating system commands via the mainfunction.cgi 'parameter' parameter. NOTE: This vulnerability only affects products that are no longe
- 9.8 Critical severity
DrayTek Multiple Vigor Routers OS Command Injection Exploited
On DrayTek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1, cgi-bin/mainfunction.cgi/cvmcfgupload allows remote command execution via shell metacharacters in a filename when the text/x-python-script content type is used, a different issue than CVE-202
- 9.8 Critical severity
Multiple DrayTek Vigor Routers Web Management Page Exploited
DrayTek Vigor2960 1.3.1_Beta, Vigor3900 1.4.4_Beta, and Vigor300B 1.3.3_Beta, 1.4.2.1_Beta, and 1.4.4_Beta devices allow remote code execution as root (without authentication) via shell metacharacters to the cgi-bin/mainfunction.cgi URI. This issue has been fi