Endress+Hauser vulnerabilities
We track 8 vulnerabilities in Endress+Hauser products across 23 products. 8 are rated high or critical, and none are known to be exploited. The most recent was published on September 2, 2025.
Latest Endress+Hauser vulnerabilities
- 7.4 High severity
Promag 10 with HART: Insertion of Sensitive Information into Log File
A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gaining una
- 7.5 High severity
Endress+Hauser MEAC300-FNADE4: Storing Passwords in a Recoverable Format
The VNC application stores its passwords encrypted within the registry but uses DES for encryption. As DES is broken, the original passwords can be recovered.
- 7.5 High severity
Endress+Hauser MEAC300-FNADE4: Use of a Broken or Risky Cryptographic Algorithm
The VNC authentication mechanism bases on a challenge-response system where both server and client use the same password for encryption. The challenge is sent from the server to the client, is encrypted by the client and sent back. The server does the same enc
- 9.8 Critical severity
Endress+Hauser MEAC300-FNADE4: Improper Restriction of Excessive Authentication Attempts
The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
- 7.5 High severity
Endress+Hauser MEAC300-FNADE4: Exposure of Information Through Directory Listing
The configuration of the Apache httpd webserver which serves the MEAC300-FNADE4 web application, is partly insecure. There are modules activated that are not required for the operation of the FNADE4 web application. The functionality of the some modules pose a
- 9.8 Critical severity
Endress+Hauser MEAC300-FNADE4: Improper Restriction of Excessive Authentication Attempts
The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
- 9.8 Critical severity
Endress+Hauser MEAC300-FNADE4: Improper Restriction of Excessive Authentication Attempts
The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
- 7.5 High severity
MSC800: Missing Authentication for Critical Functionality
A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.