CyberSecBulletin

Ls-electric vulnerabilities

We track 9 vulnerabilities in Ls-electric products across 3 products. 9 are rated high or critical, and none are known to be exploited. The most recent was published on June 17, 2025.

9vulnerabilities
3critical
6high
0exploited
8.4average CVSS score

Latest Ls-electric vulnerabilities

  • 8.4 High severity

    GMWin 4: Heap-based Buffer Overflow

    CVE-2025-49850Ls-electric

    A Heap-based Buffer Overflow vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and wr

  • 8.4 High severity

    GMWin 4: Out-of-bounds Read

    CVE-2025-49849Ls-electric

    An Out-of-bounds Read vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing p

  • 7.8 High severity

    GMWin 4: Out-of-bounds Write

    CVE-2025-49848Ls-electric

    An out-of-bounds write vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing

  • 9.8 Critical severity

    XBC-DN32U: Improper Access Control

    CVE-2023-22807Ls-electric

    LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.

  • 7.5 High severity

    XBC-DN32U: Cleartext Transmission of Sensitive Information

    CVE-2023-22806Ls-electric

    LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.

  • 9.8 Critical severity

    XBC-DN32U: Missing Authentication for Critical Functionality

    CVE-2023-22804Ls-electric

    LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.

  • 7.5 High severity

    XBC-DN32U: Missing Authentication for Critical Functionality

    CVE-2023-22803Ls-electric

    LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.

  • 7.5 High severity

    XBC-DN32U: Access of Memory Location After End of Buffer

    CVE-2023-0103Ls-electric

    If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.

  • 9.1 Critical severity

    XBC-DN32U: Missing Authentication for Critical Functionality

    CVE-2023-0102Ls-electric

    LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.