CyberSecBulletin

Sielco vulnerabilities

We track 9 vulnerabilities in Sielco products across 21 products. 9 are rated high or critical, and none are known to be exploited. The most recent was published on October 26, 2023.

9vulnerabilities
5critical
4high
0exploited
9.1average CVSS score

Latest Sielco vulnerabilities

  • 9.8 Critical severity

    PolyEco1000: Improper Access Control

    CVE-2023-46665Sielco

    Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges.

  • 9.1 Critical severity

    PolyEco1000: Improper Access Control

    CVE-2023-46664Sielco

    Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind p

  • 8.1 High severity

    PolyEco1000: Improper Access Control

    CVE-2023-46663Sielco

    Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the req

  • 9.8 Critical severity

    PolyEco1000: Improper Restriction of Excessive Authentication Attempts

    CVE-2023-5754Sielco

    Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.

  • 7.5 High severity

    PolyEco1000: Improper Access Control

    CVE-2023-46662Sielco

    Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.

  • 9.8 Critical severity

    PolyEco1000: Session Fixation

    CVE-2023-0897Sielco

    Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests.

  • 8.8 High severity

    Analog FM transmitter: Cross-Site Request Forgery

    CVE-2023-45317Sielco

    The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests. This can be exploited to perform certain actions with administrative privileges if a logged-in user visits a mali

  • 9.8 Critical severity

    Analog FM transmitter: Improper Restriction of Excessive Authentication Attempts

    CVE-2023-42769SielcoEPSS 1.09%

    The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter.

  • 8.8 High severity

    Analog FM transmitter: Improper Privilege Management

    CVE-2023-41966Sielco

    The application suffers from a privilege escalation vulnerability. A user with read permissions can elevate privileges by sending a HTTP POST to set a parameter.