CyberSecBulletin
CVE-2022-25754NVD status: Modified

SCALANCE X302-7 EEC (230V): Cross-Site Request Forgery

CVE-2022-25754 is a high-severity cross-site request forgery vulnerability in SCALANCE X302-7 EEC (230V) from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected SCALANCE X302-7 EEC (230V) versions: All versions < V4.1.4. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.53% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Scalance X302-7eec Firmware to 4.1.4 or a later version.
  2. Update Scalance X304-2fe Firmware to 4.1.4 or a later version.
  3. Update Scalance X306-1ldfe Firmware to 4.1.4 or a later version.
  4. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  5. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  6. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSCALANCE X302-7 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X304-2FEAll versions < V4.1.4Not stated
SiemensSCALANCE X306-1LD FEAll versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-3All versions < V4.1.4Not stated
SiemensSCALANCE X307-3LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2All versions < V4.1.4Not stated
SiemensSCALANCE X308-2LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2LHAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2MAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2M PoEAll versions < V4.1.4Not stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.8HighNVD
CVSS 2.06.8MediumNVD

Official description

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Cross-Site Request Forgery

The web application does not, or cannot, sufficiently verify whether a request was intentionally provided by the user who sent the request, which could have originated from an unauthorized actor.

How developers prevent this class of flaw

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, use anti-CSRF packages such as the OWASP CSRFGuard. Another example is the ESAPI Session Management control, which includes a component for CSRF.
  • Ensure that the application is free of cross-site scripting issues (CWE-79), because most CSRF defenses can be bypassed using attacker-controlled script.
  • Generate a unique nonce for each form, place the nonce into the form, and verify the nonce upon receipt of the form. Be sure that the nonce is not predictable (CWE-330).

More Cross-Site Request Forgery vulnerabilities (CWE-352)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SCALANCE X302-7 EEC (230V)

All SCALANCE X302-7 EEC (230V) vulnerabilities

Recent Cross-Site Request Forgery vulnerabilities

Spotted an error? Tell us.