CyberSecBulletin
CVE-2022-25755NVD status: Modified

SCALANCE X302-7 EEC (230V): Improper Access Control

CVE-2022-25755 is a high-severity improper access control vulnerability in SCALANCE X302-7 EEC (230V) from Siemens, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected SCALANCE X302-7 EEC (230V) versions: All versions < V4.1.4. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.33% chance of exploitation within 30 days, higher than 72% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Scalance X302-7eec Firmware to 4.1.4 or a later version.
  2. Update Scalance X304-2fe Firmware to 4.1.4 or a later version.
  3. Update Scalance X306-1ldfe Firmware to 4.1.4 or a later version.
  4. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  5. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSCALANCE X302-7 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X304-2FEAll versions < V4.1.4Not stated
SiemensSCALANCE X306-1LD FEAll versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-3All versions < V4.1.4Not stated
SiemensSCALANCE X307-3LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2All versions < V4.1.4Not stated
SiemensSCALANCE X308-2LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2LHAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2MAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2M PoEAll versions < V4.1.4Not stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighNVD
CVSS 2.05.0MediumNVD

Official description

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Improper Access Control vulnerabilities (CWE-284)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SCALANCE X302-7 EEC (230V)

All SCALANCE X302-7 EEC (230V) vulnerabilities

Recent Improper Access Control vulnerabilities

Spotted an error? Tell us.