CyberSecBulletin
CVE-2022-25752NVD status: Modified

SCALANCE X302-7 EEC (230V): Use of Insufficiently Random Values

CVE-2022-25752 is a critical-severity use of insufficiently random values vulnerability in SCALANCE X302-7 EEC (230V) from Siemens, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected SCALANCE X302-7 EEC (230V) versions: All versions < V4.1.4. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.45% chance of exploitation within 30 days, higher than 74% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update Scalance X302-7eec Firmware to 4.1.4 or a later version.
  2. Update Scalance X304-2fe Firmware to 4.1.4 or a later version.
  3. Update Scalance X306-1ldfe Firmware to 4.1.4 or a later version.
  4. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  5. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSCALANCE X302-7 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X302-7 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X304-2FEAll versions < V4.1.4Not stated
SiemensSCALANCE X306-1LD FEAll versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 230V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V)All versions < V4.1.4Not stated
SiemensSCALANCE X307-2 EEC (2x 24V, coated)All versions < V4.1.4Not stated
SiemensSCALANCE X307-3All versions < V4.1.4Not stated
SiemensSCALANCE X307-3LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2All versions < V4.1.4Not stated
SiemensSCALANCE X308-2LDAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2LHAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2MAll versions < V4.1.4Not stated
SiemensSCALANCE X308-2M PoEAll versions < V4.1.4Not stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.8CriticalNVD
CVSS 2.07.5HighNVD

Official description

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Insufficiently Random Values

The product uses insufficiently random numbers or values in a security context that depends on unpredictable numbers.

How developers prevent this class of flaw

  • Use a well-vetted algorithm that is currently considered to be strong by experts in the field, and select well-tested implementations with adequate length seeds. In general, if a pseudo-random number generator is not advertised as being cryptographically secure, then it is probably a statistical PRNG and should not be used in security-sensitive contexts. Pseudo-random number generators can produce predictable numbers if the generator is known and the seed can be guessed. A 256-bit seed is a good starting point for producing a random enough number.
  • Consider a PRNG that re-seeds itself as needed from high quality pseudo-random output sources, such as hardware devices.
  • Use products or modules that conform to FIPS 140-2 to avoid obvious entropy problems. Consult FIPS 140-2 Annex C (Approved Random Number Generators).

More Use of Insufficiently Random Values vulnerabilities (CWE-330)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SCALANCE X302-7 EEC (230V)

All SCALANCE X302-7 EEC (230V) vulnerabilities

Recent Use of Insufficiently Random Values vulnerabilities

Spotted an error? Tell us.