CGM CLININET: Improper Neutralization of Input During Web Page Generation
CVE-2025-30036 is a high-severity improper neutralization of input during web page generation vulnerability in CGM CLININET from CGM, with a CVSS 4.0 base score of 8.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 2024.MS4 as the first without the flaw, so updating CGM CLININET to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.16% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update CGM CLININET to 2024.MS4 or a later version.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| CGM | CGM CLININET | before 2024.MS4 | 2024.MS4 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Attack requirements
- PresentThe target must be in a specific state or configuration for the attack to work.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Confidentiality (vulnerable system)
- HighSerious loss of confidentiality on the vulnerable system.
- Integrity (vulnerable system)
- HighSerious loss of integrity on the vulnerable system.
- Availability (vulnerable system)
- HighSerious loss of availability on the vulnerable system.
- Confidentiality (other systems)
- HighSerious loss of confidentiality on systems beyond the vulnerable one.
- Integrity (other systems)
- HighSerious loss of integrity on systems beyond the vulnerable one.
- Availability (other systems)
- HighSerious loss of availability on systems beyond the vulnerable one.
Vector: CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (cert.pl).
Official description
Stored XSS vulnerability exists in the "Oddział" (Ward) module, in the death diagnosis description field, and allows the execution of arbitrary JavaScript code. This can lead to session hijacking of other users and potentially to privilege escalation up to full administrative rights.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Input During Web Page Generation
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
How developers prevent this class of flaw
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Examples of libraries and frameworks that make it easier to generate properly encoded output include Microsoft's Anti-XSS library, the OWASP ESAPI Encoding module, and Apache Wicket.
- Understand all the potential areas where untrusted inputs can enter your software: parameters or arguments, cookies, anything read from the network, environment variables, reverse DNS lookups, query results, request headers, URL components, e-mail, files, filenames, databases, and any external systems that provide data to the application. Remember that such inputs may be obtained indirectly through API calls.
- For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
More Improper Neutralization of Input During Web Page Generation vulnerabilities (CWE-79)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in CGM CLININET
- 9.3 Critical severity
- 8.8 High severity
- 9.4 Critical severity
- 9.4 Critical severity
- 9.0 Critical severity
- 8.6 High severity
Recent Improper Neutralization of Input During Web Page Generation vulnerabilities
- 7.3 High severity
- 9.0 Critical severity
- 8.5 High severity
- 9.6 Critical severity
- 7.1 High severity
- 8.2 High severity
Spotted an error? Tell us.