CVE-2025-30055NVD status: Deferred

CGM CLININET: Improper Control of Generation of Code

CVE-2025-30055 is a critical-severity improper control of generation of code vulnerability in CGM CLININET from CGM, with a CVSS 4.0 base score of 9.0 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists version 2024.MS4 as the first without the flaw, so updating CGM CLININET to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.23% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update CGM CLININET to 2024.MS4 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
CGMCGM CLININETbefore 2024.MS42024.MS4

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
PresentThe target must be in a specific state or configuration for the attack to work.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
HighSerious loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
HighSerious loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (cert.pl).

Official description

The "system" function receives untrusted input from the user. If the "EnableJSCaching" option is enabled, it is possible to execute arbitrary code provided as the "Module" parameter.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Control of Generation of Code

The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.

How developers prevent this class of flaw

  • Refactor your program so that you do not have to dynamically generate code.
  • Run your code in a jail or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which code can be executed by your product. Examples include the Unix chroot jail and AppArmor. In general, managed code may provide some protection. This may not be a feasible solution, and it only limits the impact to the operating system; the rest of your application may still be subject to compromise. Be careful to avoid CWE-243 and other weaknesses related to jails.
  • Use dynamic tools and techniques that interact with the product using large test suites with many diverse inputs, such as fuzz testing (fuzzing), robustness testing, and fault injection. The product's operation may slow down, but it should not become unstable, crash, or generate incorrect results.

More Improper Control of Generation of Code vulnerabilities (CWE-94)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in CGM CLININET

All CGM CLININET vulnerabilities

Recent Improper Control of Generation of Code vulnerabilities

Spotted an error? Tell us.