Siemens vulnerabilities
We track 1,652 vulnerabilities in Siemens products across 60+ products. 1,648 are rated high or critical, and 38 have been exploited in real attacks. The most recent was published on November 10, 2026.
Latest Siemens vulnerabilities
- 7.8 High severity
JT2Go: Out-of-bounds Write
Datalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.
- 7.8 High severity
Solid Edge SE2023: Out-of-bounds Write
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could
- 8.8 High severity
Siveillance Video 2020 R2: Deserialization of Untrusted Data
A vulnerability has been identified in Siveillance Video 2020 R2 (All versions < V20.2 HotfixRev14), Siveillance Video 2020 R3 (All versions < V20.3 HotfixRev12), Siveillance Video 2021 R1 (All versions < V21.1 HotfixRev12), Siveillance Video 2021 R2 (All vers
- 8.8 High severity
Siveillance Video 2020 R2: Deserialization of Untrusted Data
A vulnerability has been identified in Siveillance Video 2020 R2 (All versions < V20.2 HotfixRev14), Siveillance Video 2020 R3 (All versions < V20.3 HotfixRev12), Siveillance Video 2021 R1 (All versions < V21.1 HotfixRev12), Siveillance Video 2021 R2 (All vers
- 7.5 High severity
SIMATIC Cloud Connect 7 CC712: Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthen
- 7.5 High severity
SIMATIC Cloud Connect 7 CC712: Missing Standardized Error Handling Mechanism
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions <
- 7.6 High severity
SIMATIC Cloud Connect 7 CC712: Improper Limitation of a Pathname to a Restricted Directory
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptibl
- 7.2 High severity
SIMATIC Cloud Connect 7 CC712: Improper Neutralization of Special Elements used in a Command
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susce
- 9.9 Critical severity
SCALANCE LPE9403: Improper Neutralization of Special Elements used in an OS Command
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The web based management of affected device does not properly validate user input, making it susceptible to command injection. This could allow an authenticated remote attacker to a
- 7.8 High severity
SIMATIC S7-1500 TM MFP - GNU/Linux subsystem: Use After Free
In the Linux kernel through 6.3.1, a use-after-free in Netfilter nf_tables when processing batch requests can be abused to perform arbitrary read and write operations on kernel memory. Unprivileged local users can obtain root privileges. This occurs because an
- 7.8 High severity
SIMATIC S7-1500 CPU 1518-4 PN/DP MFP: Out-of-bounds Write
ncurses before 6.4 20230408, when used by a setuid application, allows local users to trigger security-relevant memory corruption via malformed data in a terminfo database file that is found in $HOME/.terminfo or reached via the TERMINFO or TERM environment va
- 7.4 High severity
SCALANCE X200-4P IRT: Inadequate Encryption Strength
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions <
- 7.8 High severity
JT Open: Out-of-bounds Read
A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This co
- 7.5 High severity
Polarion ALM: Improper Restriction of XML External Entity Reference
A vulnerability has been identified in Polarion ALM (All versions < V22R2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
- 7.5 High severity
SIPROTEC 5 6MD85 (CP300): NULL Pointer Dereference
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80
- 9.8 Critical severity
CP-8031 MASTER MODULE: Improper Neutralization of Special Elements used in a Command
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operatio
- 7.8 High severity
Totally Integrated Automation Portal (TIA…: Improper Limitation of a Pathname to a Restricted Directory
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All version
- 7.5 High severity
SIMATIC CP 1242-7 V2: Allocation of Resources Without Limits or Throttling
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243
- 7.5 High severity
SIMATIC CP 1242-7 V2: Deadlock
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243
- 7.5 High severity
SIMATIC CP 1242-7 V2: Use After Free
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243
- 8.8 High severity
https://github.com/curl/curl: Improper Limitation of a Pathname to a Restricted Directory
A path traversal vulnerability exists in curl <8.0.0 SFTP implementation causes the tilde (~) character to be wrongly replaced when used as a prefix in the first path element, in addition to its intended use as the first element to indicate a path relative to
- 8.8 High severity
https://github.com/curl/curl: Improper Neutralization of Special Elements in Output Used by a Downstream Component
A vulnerability in input validation exists in curl <8.0 during communication using the TELNET protocol may allow an attacker to pass on maliciously crafted user name and "telnet options" during server negotiation. The lack of proper input scrubbing allows an a
- 7.1 High severity
Linux Kernel: Use After Free
A use-after-free flaw was found in nfsd4_ssc_setup_dul in fs/nfsd/nfs4proc.c in the NFS filesystem in the Linux Kernel. This issue could allow a local attacker to crash the system or it may lead to a kernel information leak problem.
- 7.0 High severity
Linux kernel: Access of Resource Using Incompatible Type
In the Linux kernel, pick_next_rt_entity() may return a type confused entry, not detected by the BUG_ON condition, as the confused entry will not be NULL, but list_head.The buggy error condition would lead to a type confused entry with the list head,which woul
- 7.5 High severity
OpenSSL: Improper Certificate Validation
A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate c
- 7.8 High severity
Kernel: Use After Free
A use-after-free flaw was found in Linux kernel before 5.19.2. This issue occurs in cmd_hdl_filter in drivers/staging/rtl8712/rtl8712_cmd.c, allowing an attacker to launch a local denial of service attack and gain escalation of privileges.
- 9.8 Critical severity
SIMATIC S7-1500 CPU 1518-4 PN/DP MFP…: Improper Access Control
ssh-add in OpenSSH before 9.3 adds smartcard keys to ssh-agent without the intended per-hop destination constraints. The earliest affected version is 8.9.
- 8.8 High severity
RUGGEDCOM CROSSBOW: Improper Neutralization of Special Elements used in an SQL Command
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The audit log form of affected applications is vulnerable to SQL injection. This could allow authenticated remote attackers to execute arbitrary SQL queries on the server database
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute cod
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Read
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attack
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute cod
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains a memory corruption vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the c
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Read
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attack
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Read
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attack
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacke
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacke
- 7.8 High severity
Tecnomatix Plant Simulation: Out-of-bounds Write
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacke
- 8.8 High severity
RUGGEDCOM CROSSBOW: Missing Authorization
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacke
- 8.8 High severity
RUGGEDCOM CROSSBOW: Missing Authorization
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions for specific write queries. This could allow an authenticated remote attacker to perform
- 7.5 High severity
Mendix SAML (Mendix 7 compatible): Improper Authentication
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.