CyberSecBulletin
CVE-2026-34775NVD status: Analyzed

electron: Improper Isolation or Compartmentalization

CVE-2026-34775 is a critical-severity improper isolation or compartmentalization vulnerability in electron, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected electron versions: < 38.8.6; >= 39.0.0-alpha.1, < 39.8.4; >= 40.0.0-alpha.1, < 40.8.4, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.29% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of electron you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on github.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Electronelectron< 38.8.6; >= 39.0.0-alpha.1, < 39.8.4; >= 40.0.0-alpha.1, < 40.8.4; >= 41.0.0-alpha.1, < 41.0.0Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.16.8MediumCNA (github.com)
CVSS 3.19.8CriticalNVD

Official description

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0, the nodeIntegrationInWorker webPreference was not correctly scoped in all configurations. In certain process-sharing scenarios, workers spawned in frames configured with nodeIntegrationInWorker: false could still receive Node.js integration. Apps are only affected if they enable nodeIntegrationInWorker. Apps that do not use nodeIntegrationInWorker are not affected. This issue has been patched in versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Isolation or Compartmentalization

The product does not properly compartmentalize or isolate functionality, processes, or resources that require different privilege levels, rights, or permissions.

How developers prevent this class of flaw

  • Break up privileges between different modules, objects, or entities. Minimize the interfaces between modules and require strong access control between them.

More Improper Isolation or Compartmentalization vulnerabilities (CWE-653)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in electron

All electron vulnerabilities

Recent Improper Isolation or Compartmentalization vulnerabilities

Spotted an error? Tell us.