CyberSecBulletin

Cognex vulnerabilities

We track 11 vulnerabilities in Cognex products across 7 products. 11 are rated high or critical, and none are known to be exploited. The most recent was published on September 18, 2025.

11vulnerabilities
2critical
9high
0exploited
8.4average CVSS score

Latest Cognex vulnerabilities

  • 7.7 High severity

    In-Sight 2000 series: Improper Restriction of Excessive Authentication Attempts

    CVE-2025-54860Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow management operations on the device such as firmware upgrades and device reboot requiring an authentication. A wrong management of login failures o

  • 8.0 High severity

    In-Sight 2000 series: Cleartext Transmission of Sensitive Information

    CVE-2025-54818Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and

  • 8.0 High severity

    In-Sight 2000 series: Authentication Bypass by Capture-replay

    CVE-2025-54810Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and

  • 8.1 High severity

    In-Sight 2000 series: Incorrect Permission Assignment for Critical Resource

    CVE-2025-54497Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke t

  • 8.8 High severity

    In-Sight 2000 series: Client-Side Enforcement of Server-Side Security

    CVE-2025-53969Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a service implementing a proprietary protocol on TCP port 1069 to allow the client-side software, such as the In-Sight Explorer tool, to perform management operations such as changing network setting

  • 8.1 High severity

    In-Sight 2000 series: Incorrect Permission Assignment for Critical Resource

    CVE-2025-52873Cognex

    Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke t

  • 8.0 High severity

    In-Sight 2000 series: Use of Hard-coded Password

    CVE-2025-54754Cognex

    An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device

  • 7.7 High severity

    In-Sight 2000 series: Incorrect Default Permissions

    CVE-2025-53947Cognex

    A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the Windows system to modify

  • 8.6 High severity

    In-Sight 2000 series: Cleartext Transmission of Sensitive Information

    CVE-2025-47698Cognex

    An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.

  • 9.1 Critical severity

    3D-A1000 Dimensioning System: Client-Side Enforcement of Server-Side Security

    CVE-2022-1525Cognex

    The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code

  • 9.8 Critical severity

    3D-A1000 Dimensioning System: Missing Authentication for Critical Functionality

    CVE-2022-1368Cognex

    The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitor